Measuring systems

LiMOS MS

The LiMOS MS power loss measuring system is used for highly accurate measurement of losses as part of the routine and type testing of distribution and…
+ Completely digital signal processing and transmission enables calibration of the entire measuring system
+ Optical signal transmission facilitate the highest electromagnetic compliance level
+ Combined voltage/current sensors allow space-saving design

LiMOS

The LiMOS power loss measuring system is used for highly accurate measurement of losses as part of the routine and type testing of power transformers.…
+ Completely digital signal processing and transmission enables calibration of the entire measuring system
+ Optical signal transmission facilitate the highest electromagnetic compliance level
+ Combined voltage/current sensors allow space-saving design

HiRES

The digital recorders HiRES are used to measure, store, and evaluate signals from up to 24 sources synchronously. Depending on the sensors used…
+ Flexible system for multiple measuring applications
+ Potential-free measurement with fiber optic probe connection
+ High measurement accuracy even when exposed to strong EMI, such as in EMI testing, high power and high current labs

TiDAS

The Temperature Data Acquisition System (TiDAS) is an individually scalable, high performance measuring system, designed to measure temperature values…
+ Precise temperature measurement under harsh conditions
+ Various application possibilities (installation in the control cabinet but also use of the device directly in the laboratory)
+ Wide range of accessories (sensors, extension cables, etc.)

MU17 / MU18

Peak voltmeters measure the value of the voltage applied to the high-voltage dividers or the voltage up to a maximum of 1000 V directly. They can…
+ High measurement accuracy thanks to automatic switching of measurement range
+ Graphic display of the voltage curve
+ Breakdown detection during test

MKF

Measuring sphere spark gaps are mainly used for performance checks of high-voltage measurements according to IEC 60060-2:1994. If the measuring sphere…
+ Simple control option for high-voltage measurement (especially for demonstration and training purposes)
+ Movable by means of rollers or air cushions, which can be attached to the base

SMW

The impulse current shunts are designed for impulse current measurements on low inductive test objects. They are primarily used for impulse current…
+ Broadband pulse current measurement up to the Mhz range
+ Shunt is calibrated in the HIGHVOLT calibration laboratory according to IEC 60060-02 and then receives a DakkS calibration certificate

MCP

High-voltage dividers are used to measure voltages and decouple partial discharges in high-voltage test systems. Depending on the specific type, they…
+ Insensitive to athmospheric influences suitable for reference measurements
+ Excellent for tan-delta measurements
+ Movable by means of rollers or air cushions, which can be attached to the base

MCR

High-voltage dividers are used to measure voltages and decouple partial discharges in high-voltage test systems. Depending on the specific type, they…
+ Broadband, highly accurate voltage measurement down to the Mhz range
+ Diverse fields of application, ideal for test laboratories
+ Movable by means of rollers or air cushions, which can be attached to the base

SMR

High-voltage dividers are used to measure voltages and decouple partial discharges in high-voltage test systems. Depending on the specific type, they…
+ Special resistor for measuring lightning voltages (LI)
+ Cost-effective, robust design
+ Movable by means of rollers or air cushions, which can be attached to the base

SMC

High-voltage dividers are used to measure voltages and decouple partial discharges in high-voltage test systems. Depending on the specific type, they…
+ Wide range of applications even outside the high frequency range (up to 50/60 Hz)
+ Movable by means of rollers or air cushions, which can be attached to the base
+ Divider is calibrated in the HIGHVOLT calibration laboratory according to IEC 60060-02 and then receives a DakkS calibration certificate

WCR

High-voltage dividers are used to measure voltages and decouple partial discharges in high-voltage test systems. Depending on the specific type, they…
+ High stability for fixed installation in bus bar systems
+ Low temperature coefficient minimizes measurement errors with changing temperatures
+ Divider is calibrated in the HIGHVOLT calibration laboratory according to IEC 60060-02 and then receives a DakkS calibration certificate

GMR

High-voltage dividers are used to measure voltages and decouple partial discharges in high-voltage test systems. Depending on the specific type, they…
+ Special resistor exclusively for measuring DC voltage, cost-effective design
+ High-precision measuring unit, ideal for use in test laboratories
+ Movable by means of rollers or air cushions, which can be attached to the base

WC

High-voltage dividers are used to measure voltages and decouple partial discharges in high-voltage test systems. Depending on the specific type, they…
+ Measurement of mains voltage (50/60 Hz), in special cases also for measurement of AC voltage up to max. 300 Hz
+ Ideal for voltage measurement on variable frequency resonance systems
+ Movable by means of rollers or air cushions, which can be attached to the base

RM4

The ratiometer RM4 measures the divider ratio of AC and impulse voltage dividers according to IEC 60060-02. Divider ratios between 1:1 and 1:10.000…
+ Automatic measuring range for convenient operation
+ Highly portable unit
+ Maintenance free, rechargeable battery

Measurement of Turns Ratio and Vector Group

The measurement of the transformer's transformation ratio and vector group ensures that its function is guaranteed according to the rating plate.…
+ Important verification of the operating equipment parameters for their correct function
+ Especially necessary when operating several transformers in parallel

Measurement of Winding Resistance on transformers and shunt reactors

Winding resistance measurement can be used to verify the quality of the winding and its internal connections. It is also possible to check whether…
+ Non-destructive testing of the quality of a winding by determining the DC resistance component
+ Precise measurement of resistance values (< 1mΩ)

Partial Discharge measurement

PD measurement is a supplement to high-voltage testing and is part of routine and type testing of numerous electrical devices. It is one of the most…
+ Non-destructive testing for insulation faults that could lead to failures of the equipment in the future
+ Integration of measurement results in HICOS control (e.g. for automatically generated reports)
+ Selection of devices that can be provided for the particular test specimen, according to the customer's requirements

Tan-Delta measurement

The Tan-Delta measurement effectively determines the condition of the insulation of electrical equipment and is used in particular for medium and high…
+ Non-destructive testing of insulation quality
+ Integration of measurement results in HiCOS Plus control (e.g. for automatically generated reports)
+ Application-related devices, which can be selected for the respective test specimen, according to the customer's requirements
Show more